Half-bridge driver generates 100-V, 5-microsecond, 10-A pulses for lightning-strike surge simulation

Lightning causes a large current spike when it strikes a telephone line. The output of a DSL line driver could be destroyed by this surge current. To ensure robust operation, protection circuitry is used and the output of the driver needs to be tested to the “worst case” standard of 2.5 kV.

However, communication companies commonly use primary and secondary sets of protection circuitry, so the actual assault on the line driver is reduced. DSL drivers must be tested to quantify what the output can withstand without failure. Since equipment that simulates the power in a lightning strike is not readily available, Figure 1 presents a circuit that combines a 5-volt trigger with a high-voltage supply to generate the power needed to test the resilience of a DSL driver's output.



(Click to Enlarge Image)
Figure 1: Diagram of high-voltage/high-current pulse generator.

Two MOSFETs, Q1 and Q2, are driven alternatively by pulses 1 and 2 through a half-bridge driver, the HIP2100. The half-bridge driver uses a charge pump and level shifters to provide larger pulses at its output pins (pins 3 and 8).

Figure 2 displays the time domain output of the power surge circuit. The top trace is displayed with 50 V/division showing approximately 90 V of peak-to-peak voltage. With 20 V peak-to-peak appearing on the amplifier side of the series back-match resistor (and on the lower trace in Figure 2), the voltage drop allows calculation of the surge current and power.

(90 V-20 V) / 12.4 Ω = 5.6 A
20 V x 5.6 A = 112 watts

The current forced into the output of the amplifier causes a reverse bias of the PN junction of the transistors at the output stage. The reverse bias break down for the transistors at the output stage for each amplifier will depend on design and process. Some designers guarantee a maximum of 1A of allowed surge current before the loss of regulation of the transistor.

Better DSL line drivers can withstand surge currents up to 2.5 A. For a DSL line driver to withstand anything above 2.5A is exceptional. Therefore, this circuit will adequately test the resilience of the line driver.



(Click to Enlarge Image)
Figure 2: Output of the high-voltage/high-current pulse generator.

About the author
Raymond Ho is an Applications Engineer at Intersil Corp., Milpitas, CA, supporting DSL line driver products. He received his BS in Mathematics at San Jose State University.