Why are my DAC and ADC responses drooping?

Have you ever experienced unexpected droop when you’ve plotted out the frequency response of a signal processing system?  When you expected that the frequency response would be flat (or at least accurate to the curve you designed to), but instead it rolls smoothly and lazily away from that target value, insulting you with its casual sogginess?  If so, you’ve experienced the consequence of having a sinc() frequency response. You could say that you’ve had a clo-sinc-ounter – though possibly of a kind other than the third. Let’s look at what I mean by that.

This issue can crop up both at the input to and the output from a sampled data system. Let’s look at the output first. When you want to turn a stream of sample values back into an analog system, you apply those digital samples to a DAC. Now, most DAC ICs and modules have a ‘held’ output. That means that when they receive a new digital sample the output voltage changes promptly to the corresponding new value – and stays there, until the next sample comes along.

This behavior is so commonplace that many engineers assume that it’s the norm and that the output voltage of such DACs somehow represents the sample stream correctly (apart from a bit of pesky high-frequency noise).

This is not true . This ‘hold’ process causes the frequency response of such a system to differ from that of a system where the output voltage is only asserted very briefly at each sample instant. Such a spiky output voltage is hardly ever convenient in a real world application, which is why you rarely encounter it.

Stretching each sample’s voltage out to ‘fill the space available’ is an example of a zero-order hold. The output frequency spectrum of such a system is equal to that of an ideal, spiky-output system multiplied by the spectrum of the rectangular impulse that fits between two sample points, i.e. has a width equal to the sample interval. Such a rectangular time response corresponds to a frequency response that has a sinc() characteristic. sinc(x) is shorthand for sin(x)/x, and there’s a Fourier looking-glass correspondence between rectangular in one domain and sinc() in another that crops up all over the place, not only in signal theory but in the whole of physics.

Calculating the value of the sinc function – the value of the argument x is pi times the ratio of signal frequency to sampling frequency – shows that the droop is already -3 dB at around 0.444 times Fs.

This article, by prolific author Kendall Castor-Perry (aka The Filter Wizard ), explores the topic of ADC/DCA droop, its causes, and ways to accommodate it. Click to read “Why are my DAC and ADC responses drooping?,” which originally appeared at EE Times—Europe .

About the author
Kendall Castor-Perry is a Principal Architect at Cypress Semiconductor,doing mixed-signal system analysis and design for the new PSoC platform. Kendall uses decades of experience in analog engineering, filtering and signal processing to capture signals across many domains, extract the information from them and do something useful with it.

Editor’s note : Liked this? Want more?

If you are interested in “analog” issues such as signal input/output (sensors and transducer, real-world I/O); interfacing (level shifting, drivers/receivers); the signal chain; signal processing (op amps, filters, ADCs and DACs); and signal integrity, then go to the Planet Analoghome page for the latest in design, technology, trends, products, and news. Also, sign up for our weekly Planet Analog Newsletter .

0 comments on “Why are my DAC and ADC responses drooping?

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.